  1. 2010
    2010
    Triplett Railroad Testers, 2000 Series
    Item Number
    2010
    MFG Item Number
    2010
    Series
    2000
    Product Description
    Model 2000 Railroad Test Set with
    Specifications
    Specifications
    AC Voltage Range 1.5 VAC, 3 VAC, 15 VAC, 150 VAC, 300 VAC, 600 VAC
    DC Voltage Ranges 0.6 VDC, 3 VDC, 15 VDC, 60 VDC, 300 VDC
    AC Current Range 1.5 A, 6 A, 30 A
    DC Current Ranges 0.015 A, 0.06 A, 0.3 A, 1.5 A, 6 A, 30 A
    Resistance Ranges 5 Ohms, 500 Ohms
    AC Voltage Accuracy 3 %
    DC Voltage Accuracy 1.5 %
    AC Current Accuracy 3 %
    DC Current Accuracy 1.5 %
    Resistance Accuracy 2 %
    Code Function - On Time 3-100 %
    Increase
    Decrease
    Availability
  2. 2011
    2011
    Triplett Railroad Testers, 2000 Series
    Item Number
    2011
    MFG Item Number
    2011
    Series
    2000
    Product Description
    Model 2001 Railroad Test Set with
    Specifications
    Specifications
    AC Voltage Range 1.5 VAC, 3 VAC, 15 VAC, 150 VAC, 300 VAC, 600 VAC
    DC Voltage Ranges 0.6 VDC, 3 VDC, 15 VDC, 60 VDC, 300 VDC
    AC Current Range 1.5 A, 6 A, 30 A
    DC Current Ranges 0.015 A, 0.06 A, 0.3 A, 1.5 A, 6 A, 30 A
    Resistance Ranges 5 Ohms, 500 Ohms
    AC Voltage Accuracy 3 %
    DC Voltage Accuracy 1.5 %
    AC Current Accuracy 3 %
    DC Current Accuracy 1.5 %
    Resistance Accuracy 2 %
    Cab Filter 100 Hz, 250 Hz
    Code Function - On Time 3-100 %
    Increase
    Decrease
    Availability
    Order by 5:00 PM ET and your package will ship the same day.
  3. 2012
    2012
    Triplett Railroad Testers, 2000 Series
    Item Number
    2012
    MFG Item Number
    2012
    Series
    2000
    Product Description
    Model 2002 Railroad Test Set with
    Specifications
    Specifications
    AC Voltage Range 1.5 VAC, 3 VAC, 15 VAC, 150 VAC, 300 VAC, 600 VAC
    DC Voltage Ranges 0.6 VDC, 3 VDC, 15 VDC, 60 VDC, 300 VDC
    AC Current Range 1.5 A, 6 A, 30 A
    DC Current Ranges 0.015 A, 0.06 A, 0.3 A, 1.5 A, 6 A, 30 A
    Resistance Ranges 5 Ohms, 500 Ohms
    AC Voltage Accuracy 3 %
    DC Voltage Accuracy 1.5 %
    AC Current Accuracy 3 %
    DC Current Accuracy 1.5 %
    Resistance Accuracy 2 %
    Cab Filter 100 Hz, 200 Hz
    Code Function - On Time 3-100 %
    Increase
    Decrease
    Availability
    Order by 5:00 PM ET and your package will ship the same day.
  4. 2013
    2013
    Triplett Railroad Testers, 2000 Series
    Item Number
    2013
    MFG Item Number
    2013
    Series
    2000
    Product Description
    Model 2003 Railroad Test Set with
    Specifications
    Specifications
    AC Voltage Range 1.5 VAC, 3 VAC, 15 VAC, 150 VAC, 300 VAC, 600 VAC
    DC Voltage Ranges 0.6 VDC, 3 VDC, 15 VDC, 60 VDC, 300 VDC
    AC Current Range 1.5 A, 6 A, 30 A
    DC Current Ranges 0.015 A, 0.06 A, 0.3 A, 1.5 A, 6 A, 30 A
    Resistance Ranges 5 Ohms, 500 Ohms
    AC Voltage Accuracy 3 %
    DC Voltage Accuracy 1.5 %
    AC Current Accuracy 3 %
    DC Current Accuracy 1.5 %
    Resistance Accuracy 2 %
    Cab Filter 60 Hz, 100 Hz
    Code Function - On Time 3-100 %
    Increase
    Decrease
    Availability
    Order by 5:00 PM ET and your package will ship the same day.
  5. 2010-NIST
    2010-NIST
    Triplett Railroad Testers, 2000 Series
    Item Number
    2010-NIST
    MFG Item Number
    2010-NIST
    Series
    2000
    Product Description
    2010 RR Tester Kit with Certificate
    Specifications
    Specifications
    AC Voltage Range 1.5 VAC, 3 VAC, 15 VAC, 150 VAC, 300 VAC, 600 VAC
    DC Voltage Ranges 0.6 VDC, 3 VDC, 15 VDC, 60 VDC, 300 VDC
    AC Current Range 1.5 A, 6 A, 30 A
    DC Current Ranges 1.5 A, 6 A, 30 A
    Resistance Ranges 5 Ohms, 500 Ohms
    AC Voltage Accuracy 3 %
    DC Voltage Accuracy 1.5 %
    AC Current Accuracy 3 %
    DC Current Accuracy 1.5 %
    Resistance Accuracy 2 %
    Cab Filter 60 Hz, 250 Hz
    Code Function - On Time 3-100 %
    Backlight No
    Increase
    Decrease
    Availability
    Order by 5:00 PM ET and your package will ship the same day.
  6. 2011-NIST
    2011-NIST
    Triplett Railroad Testers, 2000 Series
    Item Number
    2011-NIST
    MFG Item Number
    2011-NIST
    Series
    2000
    Product Description
    2011 RR Tester Kit with Certificate
    Specifications
    Specifications
    AC Voltage Range 1.5 VAC, 3 VAC, 15 VAC, 150 VAC, 300 VAC, 600 VAC
    DC Voltage Ranges 0.6 VDC, 3 VDC, 15 VDC, 60 VDC, 300 VDC
    AC Current Range 1.5 A, 6 A, 30 A
    DC Current Ranges 1.5 A, 6 A, 30 A
    Resistance Ranges 5 Ohms, 500 Ohms
    AC Voltage Accuracy 3 %
    DC Voltage Accuracy 1.5 %
    AC Current Accuracy 3 %
    DC Current Accuracy 1.5 %
    Resistance Accuracy 2 %
    Cab Filter 60 Hz, 255 Hz
    Code Function - On Time 3-100 %
    Backlight No
    Increase
    Decrease
    Availability
    Order by 5:00 PM ET and your package will ship the same day.
  7. 2012-NIST
    2012-NIST
    Triplett Railroad Testers, 2000 Series
    Item Number
    2012-NIST
    MFG Item Number
    2012-NIST
    Series
    2000
    Product Description
    2012 RR Tester Kit with Certificate
    Specifications
    Specifications
    AC Voltage Range 1.5 VAC, 3 VAC, 15 VAC, 150 VAC, 300 VAC, 600 VAC
    DC Voltage Ranges 0.6 VDC, 3 VDC, 15 VDC, 60 VDC, 300 VDC
    AC Current Range 1.5 A, 6 A, 30 A
    DC Current Ranges 1.5 A, 6 A, 30 A
    Resistance Ranges 5 Ohms, 500 Ohms
    AC Voltage Accuracy 3 %
    DC Voltage Accuracy 1.5 %
    AC Current Accuracy 3 %
    DC Current Accuracy 1.5 %
    Resistance Accuracy 2 %
    Cab Filter 100 Hz, 200 Hz
    Code Function - On Time 3-100 %
    Backlight No
    Increase
    Decrease
    Availability
    Order by 5:00 PM ET and your package will ship the same day.
  8. 2013-NIST
    2013-NIST
    Triplett Railroad Testers, 2000 Series
    Item Number
    2013-NIST
    MFG Item Number
    2013-NIST
    Series
    2000
    Product Description
    2013 RR Tester Kit with Certificate
    Specifications
    Specifications
    AC Voltage Range 1.5 VAC, 3 VAC, 15 VAC, 150 VAC, 300 VAC, 600 VAC
    DC Voltage Ranges 0.6 VDC, 3 VDC, 15 VDC, 60 VDC, 300 VDC
    AC Current Range 1.5 A, 6 A, 30 A
    DC Current Ranges 1.5 A, 6 A, 30 A
    Resistance Ranges 5 Ohms, 500 Ohms
    AC Voltage Accuracy 3 %
    DC Voltage Accuracy 1.5 %
    AC Current Accuracy 3 %
    DC Current Accuracy 1.5 %
    Resistance Accuracy 2 %
    Cab Filter 60 Hz, 100 Hz
    Code Function - On Time 3-100 %
    Backlight No
    Increase
    Decrease
    Availability
    Order by 5:00 PM ET and your package will ship the same day.
per page

Test & Measurement

Test and measurement equipment measure, detect and record values and conditions for machinery, equipment and work environments. These devices are often handheld, with straightforward operating characteristics and the durability needed to work in the field.

The primary electronics testing device is the digital multimeter (DMM), a test tool used to measure electrical values. The basic requirement of the multimeter is the ability to test voltage, current and resistance, but many modern digital multimeters offer greater functionality.

Standalone meters can measure any one variable at a time, sacrificing flexibility for lower costs. These include resistance meters, volt meters or volt pens, and more specific measurement devices like phase rotation testers, anemometers, distance meters and more. In many cases, improved technology, much of this equipment can provide non-contact measurements and even connect to smartphones or PCs to save data and transmit results over local networks.